Graphics Elements: Difference between revisions

From Smart LCD
Created page with "== Tachometer(TCM) - Hand Mode == 128x128px right '''General''' - Show the basic information of the element - X and Y is the location of element on screen (top-left corner of the screen = 0,0) element top-left corner is the reference point - Width and Height are in pixels '''Style''' - Mode options: Hand / Donut / Icon / Pseudo Icon - Direction could be Clockwise or Anticlockwise - Start Angle is corresponding t..."
 
Line 2: Line 2:
[[File:HND.png|128x128px]]
[[File:HND.png|128x128px]]
[[File:Properties TCM HAND.png|right]]
[[File:Properties TCM HAND.png|right]]
'''General'''
Show the basic information of the element
<u>X</u> and <u>Y</u> is the location of element on screen, reference point is element top-left corner
<u>Width</u> and <u>Height</u> are in pixels
top-left corner of the screen = 0,0
'''Style'''
Mode is touch action way
Absolute=give the value direct proportion to the element area
Direction is for the slider direction Clockwise or Counterclockwise
External Radius define the outer boundary of the sensing ring (*1)
Internal Radius define the inner boundary of the sensing ring (*1)
Start Angle is the angular location of the min value (*2)
Sweep Angle is the effective angular area that relatively begin form the Start Angle for sensing (*2)
(the above 4 value define the boundary of the sensing area)
'''Content'''
VP Resource is the type of VP to be used
VP Address is the VP for the operation
Min Value is the bottom value that will be limited by the operation
Max Value is the top value that will be limited by the operation
'''Return'''
Value, VP and Status VP can be (multiply) sent to host as notification
Return Value
Up, PGID+TPKID / Down, PGID+TPKID
Return VP
Up, VP Address+Value / Down, VP Address+Value / Cycling, VP Address+Value
Return Status VP
Up, Vp Address+Status Value / Down, Vp Address+Status Value
'''General'''
'''General'''



Revision as of 17:18, 24 May 2025

Tachometer(TCM) - Hand Mode

General
Show the basic information of the element
X and Y is the location of element on screen, reference point is element top-left corner
Width and Height are in pixels
top-left corner of the screen = 0,0
Style
Mode is touch action way
Absolute=give the value direct proportion to the element area
Direction is for the slider direction Clockwise or Counterclockwise
External Radius define the outer boundary of the sensing ring (*1)
Internal Radius define the inner boundary of the sensing ring (*1)
Start Angle is the angular location of the min value (*2)
Sweep Angle is the effective angular area that relatively begin form the Start Angle for sensing (*2)
(the above 4 value define the boundary of the sensing area)
Content
VP Resource is the type of VP to be used
VP Address is the VP for the operation
Min Value is the bottom value that will be limited by the operation
Max Value is the top value that will be limited by the operation 
Return
Value, VP and Status VP can be (multiply) sent to host as notification 
Return Value
Up, PGID+TPKID / Down, PGID+TPKID
Return VP
Up, VP Address+Value / Down, VP Address+Value / Cycling, VP Address+Value
Return Status VP
Up, Vp Address+Status Value / Down, Vp Address+Status Value

General

- Show the basic information of the element

- X and Y is the location of element on screen

(top-left corner of the screen = 0,0)

element top-left corner is the reference point

- Width and Height are in pixels


Style

- Mode options: Hand / Donut / Icon / Pseudo Icon

- Direction could be Clockwise or Anticlockwise

- Start Angle is corresponding to the Min Value of content

(0° denote as the Foreground Icon original orientation)

- Sweep Angle is corresponding to the Value range

(180° denote as the Foreground Icon rotated by 180°)


Background

- Marking & Label Enable can generate the meter face details

- Base Color, Label, Minor Marking can be enable and define at here

- Label Min Value and Label Max Value is for meter face only

It show beside the Major Marking


Foreground

- Hands Type can be Line / Quadrangle / Trangle

- Hands Color is for the pointer color

- Center Mark Color is color mark at the center of the meter


Rotation Center Point

- Rotation Center Point could be Icon Center (auto select) or by manual

- Rotation Center X , Y define the the rotation reference point


Content

- VP Resource is the type of VP hold the content (VP_N16 by default)

- VP Address is the VP that hold the value

- Min Value is the minimum tachometer value to be show

(value smaller than this value will stop at the min location)

- Max Value is the maximum tachometer value to be show

(value bigger than this value will stop at the max location)


Properties Control (advance feature)

- Enable VP is none by default (element operate normally)

Select a VP for real time element control.

VP value will set to 1 as enable at power-on.

It can be disabled (hidden) by a zero value

- Hands Type VP is for changing the hand shape for visual effect

VP value will copy the above selection at power-on.

- Color VP is for changing the color for visual effect

VP value will copy the above selected Color at power-on